Sign In | Join Free | My futurenowinc.com
China Suzhou Yangyi Vouch Testing technology Co.,Ltd logo
Suzhou Yangyi Vouch Testing technology Co.,Ltd
Produce the best fire testing equipment!!! Fire testing equipment complete solution provider and service providers.
Active Member

6 Years

Home > Cone Calorimeter >

Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660

Suzhou Yangyi Vouch Testing technology Co.,Ltd

Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660

Brand Name : VOUCH

Model Number : 6810

Certification : ISO

Place of Origin : CHINA

MOQ : 1SET

Price : NEGOTIABLE

Payment Terms : TT

Supply Ability : 10SETS PER MONTH

Delivery Time : 110DAYS

Packaging Details : STANDARD EXPORT PACKAGE

Material : Sus304 stainless Steel

Package : Standard Export Package

Delivery : 59days

Standard : ISO5660

Power : 220V

Sample : Standard Sample

Application : Laboratory Cone Calorimeter

Manual : Supplied

Contact Now

Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660

Cone Calorimeter

Cone Calorimeter measures heat release rate(H.R.R), smoke release, ignition time, oxygen consumption, carbon monoxide and carbon dioxide generation and mass loss rate when specimen is exposed to resource of conical heater.


The name of Cone Calorimeter is derived from the conical heater as used by Dr. Vytenis Babrauskas to inspect test specimen (100mm*10mm) with flux up to 100kW/m2 for the bench scale oxygen depletion of his development.


ISO 5660 Building Materials Cone Calorimeter is based on the theory that pure combustion calories are in proportion to a necessary amount of oxygen for combustion and 13.1 MJ/kg is generated whenever oxygen 1kg is consumed, and heat emission, ignition time, oxygen consumption, CO and CO2 generation, and flow of ignited gases as generated from test materials are measured.


ISO 5660 Building Materials Cone Calorimeter is made for easily controlling the whole parts with DAQ (Data Acquisition) Program in a laboratory. And 19’’ touch screen helps to test automatically as well as reduce installation space.


Additionally, Conical Heater 5 Step Heat Flux Controller (optional part for R&D purpose) helps to measure combustion characteristic about specimen by temperature change and temperature rising time after setting up virtual temperature of real fire conditions. This option helps to measure various results similar to real fire environment. User can set up the user's temperature, rising speed and lasting time after rising with 5 Step Heat Flux Controller and use easily.

Model: 6810 Cone Calorimeter

Accord with standard:ISO 5660 /ASTM E 1354/GB T16172

Technology data:

1.) 19inch standard instrument frame,17inch touchable screen pc insert

2.) cone heater powering rating:5000w,heat output rate:0~100kw/m2

3.) in the range of 50*50mm in the center surface of expose test sample ,center irradiation error no more than +-2%;

4.) sample size:100mm*100mm*50mm

5.) weight range:0~2000g;precision:0.1g;

6.) ignition system with safe cut device high pressure spark generator ,automatic positioning

7.) clockwise magnetic oxygen analyzer ,adopt pressure change of clockwise magnetic to measure the oxygen density

8.) density range:0-25%,T90<1.5S,zero drift:<0.5%month,measure data deviation<0.5%month,

9.) non-dispersion infrared co and co2 analyzer:co:0~1%;co2:0~10%;

10.) smoke analyzer use laser system test smoke density,and this system was made up of photoelectricity two-electrode valve,0.5mv He-Ne laser,main graphics detector and auxiliary graphics detector .

11.) exhaust system was made up of fan,hottle,air intake and exhaust tube of fan and orifice meter.exhaust gas flow 0~50g/s can be adjusted,precision 0.1g/s.

12.) ring sampler need to be located in the air take tube at distance of 685mm against hottle ,need to be 12 holes existed in the sampler in order to homogeneous air flow component.

13.) exhaust gas flow need to be measured by the differencial pressure of side of hole plate above the fans at the distance of 350mm,the inner diameter of hole plate is 57mm+-1mm;

14.) the temperature of air flow is tested by armored thermocouple with closed node of diameter 1.6mm,thermocouple need to be located in 100 mm above the orifice plate;

15.) gas sampling system including ring sampler ,sampling pump,filter,cold trap,waste water exhaust,water filter and co2 filter;

16.) cold trap:0~5 degree,diaphragm pump,flow rate :261/min,vacuum degree:700mm Hg,pressure:2.5bar

17.) temperature controller instrument can be automatically adjust in 0-1000℃,both setted resolution and temperature control precision is +-2degree,and supply automatic cold end compensator with thermocouple

18.) use carton foil type heat flow meter ,design range 0~100k w/m2,diameter of radiation receiving target is

12.5mm,surface with durable dull black coating.radiation receiving target is cooling water method. Precision

of heat flow meter is 3%,repeatability is +0-0.5%,attached a adjust report can be date back to NIST.

19.) supply portable cooling water system.when use heat flow meter ,users do not need to tap and equipped with water.

20.) In order to calibrate the response of the whole test system, a square hole with a square hole and a square yellow copper tube is used as the calibration burner for measuring the C- coefficient values.

21.) Data acquisition system should be able to record the oxygen analyzer, orifice meter, thermocouple and other instruments of the output.

22.) Equipped with software operating system, the test results include: heat release rate, gas flow rate, C coefficient, sample time and time, total oxygen consumption, total smoke, mass loss rate, total heat release, effective combustion heat, carbon dioxide emissions and carbon dioxide emissions.

Soft ware instruction of cone calorimeter:

1.) Set in order to calibrate the sensor, including the oxygen analyzer, carbon dioxide analyzer, carbon monoxide analyzer, micro pressure difference sensor, smoke density measurement system, weighing device, mass flow control single or double point calibration, in order to obtain the best linear;

2.) C- coefficient calibration, the software can automatically set the C coefficient measurement of gas flow, such as 1KW, 3KW or 5KW, the computer system automatically calculates the ISO 5660 C coefficient and the average C coefficient, and can save the record;

3.) The software can automatically generate the C- coefficient log, which is convenient for the user to view the history of the cone calorimeter, and to identify the accuracy and stability of the system;

4.) The system can automatically calculate the delay time of the oxygen analyzer, the carbon dioxide analyzer and the carbon monoxide analyzer, which is convenient for the synchronous calculation

5.) Status check interface, the working state of the various sensor components of the instrument can be clear at a glance;

6.) Can record the work value of each sensor, including micro pressure difference sensor, chimney temperature, oxygen analyzer, carbon dioxide analyzer, carbon monoxide analyzer;

7.) The report template is EXCELL format, which can display graphics and numerical model.

Structure of cone calorimeter

1.) The combustion chamber: the conical heater, the 10KV ignition device, the control circuit, the windshield, etc..

2.) Oxygen analyzer: Servomex analyser, oxygen analyzer can accurately test the content of oxygen in the air pipe in the time of the change, and then by the instantaneous oxygen concentration and oxygen consumption principle to determine the heat release of the material.

3.) Load table: a device for measuring the quality of the sample, which can accurately record the mass change of the sample in the process of combustion

4.) Smoke measurement system: He Ne laser emitter and double electron beam measuring device, which can be used to determine the specific extinction area (SEA) of the smoke in the smoke pipe.

5.)Ventilation system: the ventilation system is a sample of the combustion products from the combustion chamber to the atmosphere in the device

6.) Other improvement equipment: according to different needs, can also add other analysis device, such as the analysis of the combustion products, can increase the infrared spectrum analysis device; if the temperature distribution in the sample, the corresponding thermocouple or infrared imaging device.

7.) Auxiliary equipment: auxiliary equipment includes microcomputer processor, heat flow meter device, removing CO2 and H2O (gas), etc.

Sample size

100*100*50mm

Weight range

0-200g

precision

0.1g

Density range

0-25%

T90

<1.5S

Zero drift

<0.5%month

Measure data deviation

<0.5%month


Application:


* Building Materials
* Rail
* IMO
* Wire & Cable
* Other

Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660


Product Tags:

calorimeter apparatus

      

flame calorimeter

      
Wholesale Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660 from china suppliers

Flame Cone Calorimeter Test , Fire Resistance Testing Laboratory Universal Standard ISO5660 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Yangyi Vouch Testing technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)